Microfiltration
Industrial
Pure Water/Process
HS-PVDF Microfiltration Element Specifications
Model |
Flow Rate
GPD
(M3/D) |
Average
Micron
Rating (μm) |
Surface
Area
(ft2) |
Dimension
(in) |
| A |
B |
C |
HS-M3-4040F |
38,000(143.64) |
0.3 |
90 |
40 |
3.88 |
0.625 |
HS-M3-8040F |
151,000(570.78) |
0.3 |
350 |
40 |
7.88 |
1.187 |
Performance is based on fouling-free water at 30 psig net
driving pressure, 77°F (25 °C) and 15% recovery. Individual element performance may vary
up to 25%.



Operating Parameters:
|
Temperature: |
Maximum 50
°C |
|
pH: |
2-11 (CIP:
1-13) |
|
Pressure: |
Recommended
30 - 150 psig |
|
Free chlorine: |
Maximum
5,000 ppm-days |
|
Differential pressure: |
Maximum 15
psig per element not to exceed 50 psig per housing |
|