   HS-Polysulfone Microfiltration Element Specifications

Model

Flow Rate
GPD
(M3/D)

Average
Rejection
(%)

Surface
Area
(ft2)

Dimension
(in)

A B C

HS-M1-4026F

6,500(24.57)

98

60

26

3.38

0.625

HS-M1-4040F

11,000(41.58)

98

90

40

3.88

0.625

HS-M1-8040F

36,000(136.08)

98

350

40

7.88

1.187

Performance is based on PVA solution of 60,000 MW 11% feed at 30 psig net driving pressure,77°F (25 °C) and 10% recovery. Individual element performance may vary up to 25%.

 

 

a-1.gif (38979 bytes)

 

 

Operating Parameters:

                         Temperature: Maximum 50 °C
                         pH: 2-11 (CIP: 2-11.5)
                         Pressure: Recommended 30 - 150 psig
                         Free chlorine: Maximum  5,000 ppm-days
                         Differential pressure: Maximum 15 psig per element not to exceed 50 psig per housing

 

 