HS-PES Ultrafiltration Element Specifications

Model

Flow Rate
GPD
(M3/D)

Average
Rejection
(%)

Surface
Area
(ft2)

Dimension
(in)

A B C

HS-UF1-2540FF*

3,300(12.47)

97

27

40

2.38

0.750

HS-UF1-4040F

8,100(30.62)

97

90

40

3.88

0.625

HS-UF1-8040F

31,500(119.1)

97

350

40

7.88

1.187

Performance is based on Cytochrome-C solution of 13,300 MW protein at 30 psig net driving pressure, 77°F (25 °C) and 10% recovery. Individual element performance may vary up to 25%.

 


a-1.gif (38979 bytes)


 

Operating Parameters:

                           Temperature: Maximum 50 °C
                           pH: 2-11 (CIP: 2-11.5)
                           Pressure: Maximum 200 psig
                           Free chlorine: Maximum 5,000 ppm-days
                           Differential pressure: Maximum 15 psig per element not to exceed 50 psig per housing.

  *Stinger design

 

 