Ultrafiltration
Industrial
Pure Water/Process
HS-PES Ultrafiltration Element
Specifications
Model |
Flow Rate
GPD
(M3/D) |
Average
Rejection
(%) |
Surface
Area
(ft2) |
Dimension
(in) |
| A |
B |
C |
HS-UF1-2540FF* |
3,300(12.47) |
97 |
27 |
40 |
2.38 |
0.750 |
HS-UF1-4040F |
8,100(30.62) |
97 |
90 |
40 |
3.88 |
0.625 |
HS-UF1-8040F |
31,500(119.1) |
97 |
350 |
40 |
7.88 |
1.187 |
Performance is based on Cytochrome-C solution
of 13,300 MW protein at 30 psig net driving pressure, 77°F (25 °C) and 10% recovery.
Individual element performance may vary up to 25%.



Operating Parameters:
|
Temperature: |
Maximum 50
°C |
|
pH: |
2-11 (CIP:
2-11.5) |
|
Pressure: |
Maximum 200
psig |
|
Free chlorine: |
Maximum
5,000 ppm-days |
|
Differential pressure: |
Maximum 15
psig per element not to exceed 50 psig per housing. |
*Stinger design
|