Ultrafiltration
Industrial
Process
HS-Thin Film Composite
Ultrafiltration Element Specifications
Membrane |
Molecular Weight
Cut-off |
Element
Sizes |
Flow
Rate
GPD |
Flow Rate
Specifications |
HS-T1 |
1,000 |
2540 |
540 |
Fouling free water,400 psig
net pressure,25℃,10%recovery |
4040 |
2,000 |
8040 |
6,225 |
HS-T2 |
2,500 |
2540 |
540 |
Fouling free water,150 psig
net pressure,25℃,10%recovery |
4040 |
1,800 |
8040 |
6,800 |
HS-T3 |
3,500 |
2540 |
540 |
Fouling free water,75 psig
net pressure,25℃,10%
recovery |
4040 |
1,500 |
8040 |
5,600 |
HS-T8 |
8,000 |
2540 |
540 |
Fouling free water,40 psig
net pressure,25℃,10 %
recovery |
4040 |
1,800 |
8040 |
6,200 |
HS-TA |
10,000 |
2540 |
756 |
Fouling free water,40 psig
net pressure, 25℃,
10% recovery |
4040 |
2,520 |
8040 |
8,680 |
Operating Parameters:
|
Temperature: |
Maximum 50
°C |
pH: |
2-11 (CIP:
2-11.5) |
Pressure: |
Maximum 400
psig |
Free chlorine: |
Maximum
10-1,000 ppm-days based on model. |
Differential pressure: |
Maximum 15
psig per element not to exceed 50 psig per housing. |
| Model |
Dimension(in) |
| A |
B |
C |
| HS-T*-2540 |
40 |
2.38 |
0.750 |
| HS-T*-4040 |
40 |
3.88 |
0.625 |
| HS-T*-8040 |
40 |
7.88 |
1.187 |


Note: 2540 is stinger design
|