logo.gif (2430 bytes)  HYDROSEP INC.

seahawk.gif (6900 bytes)

 

                                               Reverse Osmosis

                                                     Residential

                                                     Pure Water

 

HS-Thin Film Composite Residential Element Specifications

Model

Flow Rate
GPD
(M3/D)

Average
Rejection
(%)

Dimension
(in)

A B C D

HS-3680

36(5.7)

97

1.5

0.678

10

11.75

HS-5080

50(7.9)

97

1.8

0.678

10

11.75

HS-7580

75(11.6)

97

1.8

0.678

10

11.75

HS-10080

100(15.8)

97

2

0.678

10

11.75

Performance is based on 500 ppm NaCl solution at 80 psig net driving pressure, 77°F (25 °C) and 20% recovery. Individual element performance may vary up to 15%

 

HS-Cellulose Acetate Residential Element Specifications

Model

Flow Rate
GPD
(M3/D)

Average
Rejection
(%)

Dimension
(in)

A

B

C

D

HS-C1680

16(2.5)

94

1.8

0.678

10

11.75

HS-C2480

24(3.8)

94

1.8

0.678

10

11.75

HS-C3280

32(5.0)

94

1.8

0.678

10

11.75

Performance is based on 500 ppm NaCl solution at 80 psig net driving pressure, 77°F (25 °C) and 20% recovery. Individual element performance may vary up to 15%

 

 

a-1.gif (38979 bytes)

 

 

Operating Parameters:

HS-Thin Film Composite Residential Products:

                        Temperature: Maximum 40 °C
                        pH 4-10
                        Pressure: Maximum 150 psig
                        Free chlorine: Maximum <0.l ppm
                        Silt density index: Maximum 5

 

HS-Cellulose Acetate Residential Products:

                    Temperature: Maximum 35 °C
                     pH: 5-8
                     Pressure: Maximum 150 psig
                     Free chlorine: Maximum <1 ppm
                     Silt density index: Maximum 5

 

 

Rejection Characteristics

Ions

HS-Thin Film Composite

HS-Cellulose Acetate

Sodium, Na+

97.4

94.0

Potassium, K+

98.1

94.5

Calcium, Ca+2

99.0

96.5

Magnesium, Mg+2

98.8

95.8

Chloride, Cl-

97.5

93.6

Alkalinity, HCO3-

97.2

92.8

Sulfate, SO4-2

99.0

96.1

Nitrate, NO3-

97.5

92.1

Silica, SiO2

97.0

93.0

TDS

98.1

94.2

Performance is based on fouling free tap water at 60 psig net driving pressure, 77°F
(25 °C), pH 7.8 and 15% recovery. Individual element performance may vary up to 15%.




Home Up Feedback Site map 

This site is best viewed with Internet Explorer & Netscape Navigator 800X600 pixel.
Send mail to hydrosep@hydrosep.com with questions or comments about this web site.
Copyright © 2000 Hydrosep Inc.
Last modified: 2001/06/30